Technical Specifications
60kW CHAdeMO + 60kW CCS-2 output
Dual gun (CHAdeMO + CCS-2)
LCD display with touchscreen
Power, Charging Status & Fault indicators
With Internet communication & RFID card options
INPUT POWER
Input Voltage (AC) – 3 Phase, 415V
Input Frequency – 50Hz
Wires 5 wires : L1,L2,L3,N,PE
OUTPUT POWER
Number of Outputs – 2
Output Connector – CCS-2 + CHAdeMO
Output Voltage DC -Vdc – 200 – 1000 Vdc
Output Rating – 120kW (60kW CCS + 60kW CHAdeMO)
ENVIRONMENT
Ambient Temperature -20⁰C to 80⁰C
Operating Temperature -20⁰C to 75⁰C
Altitude Upto 3000 mtrs
Humidity 0 to 95%
PROTECTION
Protection Over voltage, under voltage, over current, short circuit, surge protection, over temperature, emergency shutdown with alarm, protection against electric shock
Compliance & Safety IEC
USER INTERFACE & CONTROL
Display – 7” TFT LCD Touch Screen
Language – English
Emergency Stop – Mushroom type push button
User Authentication – Mobile App/ Password Login/ QR Code/ RFID
Visual Indication Error Indication, SOC, Presence of Input Supply
COMMUNICATION
Charger & CMS – OCPP 1.6 (upgradable to OCPP2.0)
Network Connection – Ethernet, Sim Card (optional at additional cost)
Interested
MECHANICAL
Charging Cable Length – 5 meters
Ingress Protection – IP54
Cooling Forced – Air Cooling
Dimensions – (W x L x H) 650mm x 500mm x 1800mm
Weight – 245 Kg
Reviews